Summary

Getting Here

Useful Information

Rooms and Spaces Links

Building Parking

  • The building does not have its own dedicated parking.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is The Queens Buildings.
    • The car park is located near the Central Building entrance.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park (The Queens Buildings)

  • Car Park View
    • The car park is located in the centre of The Queens Buildings.
    • The nearest building(s) to this car park is/are North, South, Central and West Buildings.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is block paving.
    • Designated Blue Badge parking bays are not available.
  • Charges and Restrictions View
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are clearly signposted from this car park.
    • There is not a campus map available within the car park.
    • This car park is free for parking permit holders only.
      If you aren't a permit holder you can pay by phone using the RingGo app, site number: 39356.
      If you don't have a smart phone you can call 02030460183 to pay for parking over the phone.
      There is additional on-street parking located on The Parade (photographs 7-10).
      The size of the standard marked bays are 240 x 360 centimetres.
      Charges apply via the payment machine or the Ringo app.

Outside Access

  • Entrance View
    • This information is for the entrance located in the covered walkway near the main Queens Building car parks.
    • This entrance gives access to level 0.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Central Building / Adeilad Canolog'.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • There is a dark mat or floor marking at this entrance that might be perceived as a hole.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 198cm.

Entrance (Level 0 to South Building)

  • Entrance View
    • This information is for the entrance located on level 0.
    • This entrance gives access to South Building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 170cm.

Entrance (Level 1 - to North Building)

  • Entrance View
    • This information is for the entrance located on level 1 near the lift.
    • This entrance gives access to level 1 of the North Building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width but one door is locked.
    • The door(s) is/are heavy.
    • The width of the door opening is 81cm.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 161cm.

Entrance (Level 1 - To South Building)

  • Entrance View
    • This information is for the entrance located at the southern end of the level 1 corridor.
    • This entrance gives access to level 1 of South Building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 172cm.

Entrance (Level 2 - To North Building)

  • Entrance View
    • This information is for the entrance located at the northern end of the main corridor on level 2.
    • This entrance gives access to level 2 of North Building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 158cm.

Entrance (Level 2 - to South Building)

  • Entrance View
    • This information is for the entrance located at the southern end of the level 2 corridor.
    • This entrance gives access to level 2 of South Building.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 172cm.
  • Step(s) View
    • The step(s) is/are located in South building immediately after the entrance door.
    • There is/are 15+ step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 15cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.

Entrance (Level 3 - to North Building)

  • Entrance View
    • This information is for the entrance located at the northern end of the level 3 corridor.
    • This entrance gives access to level 3 of North Building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 168cm.

Entrance (Level 3 - to South Building)

  • Entrance View
    • This information is for the entrance located at the southern end of the level 3 corridor.
    • This entrance gives access to level 3 of South Building.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 162cm.
  • Step(s) View
    • The step(s) is/are located in South Building immediately after the entrance door.
    • There is/are 15+ step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.

Entrance (Level 4 - to South Building)

  • Entrance View
    • This information is for the entrance located at the southern end of the level 4 corridor.
    • This entrance gives access to South Building.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 172cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Step(s) View
    • The step(s) is/are located in South Building immediately after passing through the entrance.
    • There is/are 15+ step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.

Getting Around

  • Access View
    • There is step-free access throughout the building .
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is vinyl and carpet.
    • There is flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • Handrails with a rounded or oval profile are not provided in corridors/walkways.
    • There is high colour contrast between the walls and floor in the majority of corridors/walkways.
    • There are no seats/chairs at regular intervals.
    • The lighting levels are varied.
  • Signage View
    • Wayfinding signage is not provided.
    • The colour, design and typeface of signs is not consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Kitchen/Dining Area (Level 2)

  • The kitchen/dining area is accessed by a single door with an opening width of over 75cm.
  • The doors are not push pad activated.
  • Lowered work surfaces are not available.
  • The height of the lowest work surface is 85cm.
  • The kitchen does have an unobstructed floor space of at least 150cm × 150cm.
  • There is a knee recess under a work surface.
  • A knee recess is provided adjacent to the sink.
  • Knee recesses are at least 80cm wide.
  • There are low level cupboards.
  • Coffee tables and permanently fixed high tables are available in this area. The heights of the tables range from 36cm to 91cm. High stools and chairs with armrests are available.

Other Floors (Main Entrance)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located ahead and to the right as you enter.
    • The stairs are approximately 6m from the main entrance.
    • The stairs are clearly visible from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on the second floor, on the fourth floor and on the third floor.
    • The floors which are accessible by the stairs are 0, 1, 2, 3, 4.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are varied.
  • Comments View
    • The steps on this staircase have open risers.

Lift (Main Entrance)

  • The lift is located ahead as you enter.
  • The lift is clearly visible from the entrance.
  • The lift is approximately 3m (3yd 10in) from the main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are 0, 1, 2, 3, 4.
  • The weight limit for the lift is 1500kg.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is high.
  • The colour contrast between the external lift control plate and the wall is high.
  • The clear door width is 152cm (4ft 12in).
  • The dimensions of the lift are 161cm x 208cm (5ft 3in x 6ft 10in).
  • There are not separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.

Accessible Toilet(s)

  • There is not an/are not accessible toilet(s) available.
  • The nearest accessible toilet(s) is/are located in North Building.

Standard Toilet(s)

  • Standard toilet facilities are not available.
  • The nearest standard toilet(s) is/are located in North Building.